Test reports.
Clearer evidence.

Explore three semi-solid cell electrolyte weight-loss records, with recorded conditions, measured masses and original before-and-after photographs.

View record
Test temperature
120°C
Test duration
6 hours
Vacuum degree as recorded
90 (-kPa)
Acceptance range in the records
1–15%

The workbooks label vacuum degree “(-kPa)” and record 90. This is reproduced as written, not converted to absolute pressure.

The results, at a glance.

One populated sample result per workbook. Percentages are rounded to two decimal places for display.

Summary of the three supplied cell test records
Cell modelWeight loss rateRecorded judgmentTest dateTest record
126280-100008.84%OKView record
486578-50006.03%OKView record
546280-50009.60%OKView record

Test record / 01

126280-10000

Test date: / Sample No.: 1

8.84%Weight loss rate · OK
Mass before test
127.58 g
Mass after test
116.30 g
Mass loss
11.28 g

Recorded samples: 1

Before test
Original before-test weighing photograph — 126280-10000
After test
Original after-test weighing photograph — 126280-10000

Test record / 02

486578-5000

Test date: / Sample No.: 1

6.03%Weight loss rate · OK
Mass before test
61.21 g
Mass after test
57.52 g
Mass loss
3.69 g

Recorded samples: 1

Before test
Original before-test weighing photograph — 486578-5000
After test
Original after-test weighing photograph — 486578-5000

Test record / 03

546280-5000

Test date: / Sample No.: 1

9.60%Weight loss rate · OK
Mass before test
61.45 g
Mass after test
55.55 g
Mass loss
5.90 g

Recorded samples: 1

Before test
Original before-test weighing photograph — 546280-5000
After test
Original after-test weighing photograph — 546280-5000

How the result is calculated.

Weight loss rate = (mass before test − mass after test) ÷ mass before test × 100%

The calculation uses the sample mass recorded in columns C and D. Column E records the difference and column F divides that difference by the initial mass.

Read the result in context.

These records describe the listed cell samples under the stated test conditions. Weight loss alone does not establish electrolyte composition, solid content, complete power-bank safety or third-party certification.

The records state an acceptance range of 1–15% and mark each populated result “OK”. No external test standard or independent certification body is identified in these files. The “Filled by” and “Reviewed by” fields are blank.

120°C and the other conditions belong to this test record. They are not charging, storage or operating ratings for a power bank.